LMG641
|
1 to 4 Channel Power Analyzer
Outstanding accuracy of 0.015% of measured value + 0.01% of range
Full dynamic range of 500 µA to 32 A / 3 mV to 1000 V per channel available in single instrument
Analog bandwidth DC up to 10 MHz
Modular configuration with 1 to 4 power measurement channels (alternatively 3 channels + 1 I/O card)
Simultaneous measurement of narrow- and broadband values through innovative DualPath architecture
Harmonics and interharmonics up to 2000. order, as required by EN61000-4-7
With optional I/O card speed/torque inputs freely configurable for all signal types (analogue, frequency as RS422,TTL or HTL) via menu
Flexible scripting tool for custom applications
Simultaneous measurement of V, I, P values and harmonics, presentation in tabular or graphical form
Synchronization to up to 4 different frequencies simultaneously
Flicker measurement, interactions between grid and appliance according to EN61000-4-15
Large and clearly arranged touchscreen GUI for intuitive handling
Internal storage of long-term measurements even with shortest cycle-time thanks to integrated mass storage device
Excellent connectivity via USB3.0, Gbit-LAN, RS-232 and DVI
Convenient "plug-and-measure" through automated sensor detection
Calibration certificate included free-of-charge in first delivery
24 months warranty
L60-CH-S S-Channel for high-precision broadband and DC-optimized measurements
DC-optimized,
with DualPath functionality, bandwidth DC-10 MHz,
best power accuracy 0.015% + 0.01%
18 bit channel resolution
Measuring inputs:
1. Voltage directly: 300 mV - 1000 Vtrms/1500VDC in 10 ranges, 3200 Vpk
2. Voltage sensor input: 3 mV - 4 Vtrms/10 VDC in 8 ranges, 12.5 Vpk
3. Current directly 500 µA-32 Atrms in 10 ranges, 120 Apk
4. Current sensor input: 3 mV - 4 Vtrms/10 VDC in 8 ranges, 12.5 Vpk
L60-CH-A A-Channel for high-precision broadband measurements
with DualPath functionality, bandwidth DC-10 MHz,
best power accuracy 0.015% + 0.01%
18 bit channel resolution
Measuring inputs:
1. Voltage directly: 300 mV - 1000 Vtrms in 10 ranges, 3200 Upk
2. Voltage sensor input: 3 mV - 4 Vtrms in 8 ranges, 12.5 Upk
3. Current directly 500 µA-32 Atrms in 10 ranges, 120 Ipk
4. Current sensor input: 3 mV - 4 Vtrms in 8 ranges, 12.5 Upk
L60-CH-B B-Channel for general purpose measurements
with DualPath functionality, bandwidth DC - 500 kHz,
best power accuracy 0.05% + 0.02%
16 bit channel resolution
Measuring inputs:
1. Voltage directly: 300 mV - 1000 Vtrms in 10 ranges, 3200 Upk
2. Current directly 500 µA-32 Atrms in 10 ranges, 120 Ipk
3. Current sensor input: 3 mV - 4 Vtrms in 8 ranges, 12.5 Upk
L60-CH-C C-Channel for high-precision measurements up to 10kHz
bandwidth DC - 10 kHz, best power accuracy 0.03% + 0.01%,
16 bit channel resolution
Measuring inputs:
1. Voltage directly: 300 mV - 1000 Vtrms in 10 ranges, 3200 Upk
2. Current directly 500 µA-32 Atrms in 10 ranges, 120 Ipk
3. Current sensor input: 3 mV - 4 Vtrms in 8 ranges, 12.5 Upk
|
|
|